4.8 Article

CuO thin film based uric acid biosensor with enhanced response characteristics

期刊

BIOSENSORS & BIOELECTRONICS
卷 38, 期 1, 页码 11-18

出版社

ELSEVIER ADVANCED TECHNOLOGY
DOI: 10.1016/j.bios.2012.03.043

关键词

Uric acid; Copper oxide; Thin film; Pulsed laser deposition; Biosensor

资金

  1. Department of Science and Technology (DST)
  2. UGC

向作者/读者索取更多资源

An efficient reagentless uric acid biosensor has been realized using a copper oxide (CuO) thin film matrix grown onto platinum (Pt) coated corning glass substrates by pulsed laser deposition (PLD) technique. The p-type CuO matrix successfully introduces redox property in the electrode and provides enhanced electron communication features. Sensing response obtained by the bioelectrocatalytic oxidation of uric acid by uricase/CuO/Pt/glass electrode was studied without any external mediator using cyclic voltammetry (CV) and photometric assay. The studies reveal that the uricase/CuO/Pt/glass bio-electrode exhibits good linearity over a wide range of 0.05 mM to 1.0 mM uric acid concentration with enhanced response of 2.7 mA/mM and high shelf life ( > 14 weeks). A low Michaelis-Menten constant (K-m) of 0.12 mM, indicate that the immobilized enzyme (uricase) has enhanced affinity towards its analyte (uric acid). The results confirm promising application of the p-type CuO thin film matrix for the realization of a reagentless integrated implantable biosensor. (c) 2012 Elsevier B.V. All rights reserved.