期刊
BIOSENSORS & BIOELECTRONICS
卷 28, 期 1, 页码 344-348出版社
ELSEVIER ADVANCED TECHNOLOGY
DOI: 10.1016/j.bios.2011.07.041
关键词
Au nanoplate; Tannic acid; Glucose biosensor; Human blood serum
The present communication demonstrates a relatively green preparative route toward Au nanoplates in aqueous solution at room temperature with the use of tannic acid (TA), which is an environmentally friendly, soluble polyphenol, as a reducing agent. Such Au nanoplates exhibit notable catalytic performance toward the oxidation and reduction of H(2)O(2). A glucose biosensor was further fabricated by immobilizing glucose oxidase (GOD) into chitosan-Au nanoplate composites film on the surface of glassy carbon electrode (GCE). This sensor exhibits good response to glucose, and the linear response range is estimated to be from 2 to 20 mM (R = 0.999) at 0.65 V and from 2 to 10 mM (R = 0.993) at -0.2 V, respectively. The sensitivity of the sensor determined from the slopes is 49.5 mu A mM(-1) cm(-2) at 0.65 V. (C) 2011 Elsevier B.V. All rights reserved.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐