4.8 Article

Glucose oxidase and ferrocene labels immobilized at Au/TiO2 nanocomposites with high load amount and activity for sensitive immunoelectrochemical measurement of ProGRP biomarker

期刊

BIOSENSORS & BIOELECTRONICS
卷 26, 期 9, 页码 3838-3844

出版社

ELSEVIER ADVANCED TECHNOLOGY
DOI: 10.1016/j.bios.2011.02.043

关键词

Au/TiO2 nanocomposites (nano-Au/TiO2); Graphene sheets (GS); Immunosensor; Ferrocene (Fc); Progastrin releasing-peptide (ProGRP)

资金

  1. NNSF of China [21075100]
  2. Ministry of Education of China [708073]
  3. Chongqing Key Laboratory on Luminescence and Real-Time Analysis [2006CA8006]
  4. Natural Science Foundation [2010BB4121]
  5. Fundamental Research Funds for the Central Universities [XDJK2010C062, XDJK2009B013]
  6. Doctor Foundation of Southwest University [SWU109016]
  7. Outstanding Youth Foundation of College of Chemistry and Chemical Engineering, Southwest University, China [SWUC009]

向作者/读者索取更多资源

Progastrin releasing-peptide (ProGRP) is a sensitive, specific, and reliable tumor marker with small cell lung cancer (SCLC), which may indicate an early tendency of cancer metastasis, causing high mortality rate. Thus, aiming for a more convenient assay system of SCLC, a novel immunoelectrochemical measurement for sensitive detection of ProGRP was developed in this work via Au nanoparticle/graphene modified immunosensor with ferrocene and glucose oxidase-multifunctionalized Au/TiO2 nanocomposites as a trace label. At first, Au nanoparticles (nano-Au) were attached on the TiO2 nanoparticles surface by using 3-aminopropyltriethoxy silane (APTES) as linkage reagent to obtain Au/TiO2 nanocomposites (nano-Au/TiO2). Next, glucose oxidase (GOD) and ferrocene labeled secondary antibodies (Fc-Ab(2)) were used to bind Au/TiO2 nanocomposites with high load amount and good biological activity, and because the increased surface area and biocompatibility of nano-Au/TiO2, the electrode can provide amplified signals. On the other hand, the nano-Au functionalized graphene sheets (GS) were used for the biosensor platform for increasing the surface area as well as improving the electronic transmission rate to capture a large amount of primary antibodies (Ab(1)). Then in presence of glucose, amplified signals can be obtained by an electrochemical sandwich immunoassay protocol. Based on the proposed immunosensor, the current is linear with the concentration of ProGRP being within a concentration range from 10.0 to 500 pg/mL with a limit of detection down to 3.0 pg/mL (S/N = 3). (C) 2011 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据