4.8 Article

SOI optical microring resonator with poly(ethylene glycol) polymer brush for label-free biosensor applications

期刊

BIOSENSORS & BIOELECTRONICS
卷 24, 期 8, 页码 2528-2533

出版社

ELSEVIER ADVANCED TECHNOLOGY
DOI: 10.1016/j.bios.2009.01.009

关键词

Silicon-on-Insulator; Microring resonator; Optical biosensor; SAM; Non-specific binding reduction; Label-free biosensor

资金

  1. Ghent University through the GOA project [B/05958/01]
  2. Flemish Institute for the Promotion of Innovation through Science and Technology (IWT) [IAP 6-10]

向作者/读者索取更多资源

Label-free monitoring of biomolecular interactions has become of key importance for the emerging proteomics field. Monitoring real time interaction kinetics and high throughput screening of complex samples is of major importance for a variety of applications. We previously reported the use of Silicon-on-Insulator photonics microring resonators for cheap disposable biosensors on chip. Silicon photonics is a platform for micro- and nanoscale integrated devices that can be fabricated at extremely low cost, with standard CMOS processing facilities. Incorporation of a hydrophilic heterobifunctional polymer coating on the silicon chips largely improved the system's response to non-specific binding. We report the chemical coating procedure, the chemical surface characterization and optical measurements for both specific and non-specific interactions. Two heterobifunctional polymer coatings were investigated, alpha-sulfanyl-omega-carboxy-poly(ethylene glycol) and monoprotected diamino-poly(ethylene glycol). Homogenous coatings with thicknesses of 2.3 and 2.5 nm were obtained, corresponding to a surface loading of 99 pm/cm(2) carboxy- and 97 pm/cm(2) aminogroups, respectively. The polymer coated sensor with covalently bound biotin receptor molecules showed very low response to Bovine Serum Albumin (BSA) up to 1 mg/ml in contrast to a high response to avidin with much lower concentrations (2, 10, 87.5 and 175 mu g/ml). By extrapolation the detection limit is about 10 ng/ml or 0.37 fg avidin mass. Comparison with the values reported for standard silanization confirms the polymer coating does not deteriorate the system's limit of detection. This makes the optical biosensor chip suitable to be integrated in a microflow system for commercial label-free biosensors and for lab-on-a-chip applications. (c) 2009 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据