4.8 Article

Optical protein sensor for detecting cancer markers in saliva

期刊

BIOSENSORS & BIOELECTRONICS
卷 24, 期 2, 页码 266-271

出版社

ELSEVIER ADVANCED TECHNOLOGY
DOI: 10.1016/j.bios.2008.03.037

关键词

optical biosensor; diagnostics; IL-8 protein; oral cancer; surface immobilization

资金

  1. UO1 Research [DEI 5018]
  2. National Institute of Dental and Craniofacial Research
  3. National Institutes of Health, Bethesda, MD [20892]

向作者/读者索取更多资源

A surface immobilized optical protein sensor has been utilized to detect Interleukin-8 (IL-8) protein, an oral cancer market, and can reach limit of detection (LOD) at 1.1 pM in buffer without using enzymatic amplification. Only after applying enzymatic amplification to increase the signal level by a few orders of magnitude, ELISA can reach the LOD of I pM level. We then develop the confocal optics based sensor for further reducing the optical noise and can extend the LOD of the surface immobilized optical protein sensor two orders in magnitude. These improvements have allowed us to detect IL-8 protein at 4.0 fM in buffer. In addition, these sensitive LODs were achieved without the use of enzymatic signal amplification, such that the simplified protocol can further facilitate the development of point-of-care devices. The ultra sensitive optical protein sensor presented in this paper has a wide number of applications in disease diagnoses. Measurements for detecting biomarkers in clinical sample are much more challenging than the measurements in buffer, due to high background noise contributed by large collections of nontarget molecules. We used clinical saliva samples to validate the functionality of the optical protein sensor. Clinical detection of disease-specific biomarkers in saliva offers a non-invasive, alternative approach to using blood or urine. Currently, the main challenge of using saliva as a diagnostic fluid is its inherently low Concentration of biomarkers. We compare the measurements of 40 saliva samples; half from oral cancer patients and half from a Control group. The data measured by the optical protein sensor is compared with the traditional Enzyme-Linked Immunosorbant Assay (ELISA) values to validate the accuracy of our system. These positive results enable us to proceed to using confocal optical protein sensor to detect other biomarkers. which have much lower concentrations. (C) 2008 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据