期刊
BIORESOURCE TECHNOLOGY
卷 129, 期 -, 页码 582-591出版社
ELSEVIER SCI LTD
DOI: 10.1016/j.biortech.2012.10.153
关键词
Algae harvesting; Submerged membrane filtration; IPC; Water recycle; Polishing
资金
- MIP Vlaanderen
The feasibility of algae harvesting with submerged flat panel membranes was investigated as pre-concentration step prior to centrifugation. Polishing of the supernatant coming from the centrifuge was evaluated as well. The effect of membrane polymer (polyvinyl chloride [PVC], polyethersulfone polyvinyl-pyrollidone [PES-PVP], poly vinylidene fluoride [PVDF]), pore size (microfiltration [MF], ultrafiltration [UF]), algae cell concentrations and species were investigated at lab-scale. In addition, backwashing as fouling control was compared to standard relaxation. PVDF was the superior polymer, and UF showed better fouling resistance. Backwashing outperformed relaxation in fouling control. The backwashable membranes allowed up to 300% higher fluxes compared to commercial flat panel benchmark (PVC) membranes. Estimations on energy consumption for membrane filtration followed by centrifugation revealed relatively low values of 0.169 kW h/kg of dry weight of algae compared to 0.5 kW h/kg for algae harvesting via classical centrifuge alone. (C) 2012 Elsevier Ltd. All rights reserved.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐
暂无数据