4.8 Article

Evaluation of near infrared spectroscopy and software sensor methods for determination of total alkalinity in anaerobic digesters

期刊

BIORESOURCE TECHNOLOGY
卷 102, 期 5, 页码 4083-4090

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.biortech.2010.12.046

关键词

Biogas; Anaerobic digestion; Monitoring; NIRS; Software sensor

资金

  1. European Social Fund
  2. UK Biotechnology and Biological Sciences Research Council

向作者/读者索取更多资源

In this study two approaches to predict the total alkalinity (expressed as mg L-1 HCO3-) of an anaerobic digester are examined: firstly, software sensors based on multiple linear regression algorithms using data from pH, redox potential and electrical conductivity and secondly, near infrared reflectance spectroscopy (NIRS). Of the software sensors, the model using data from all three probes but a smaller dataset using total alkalinity values below 6000 mg L-1 HCO3- produced the best calibration model (R-2 = 0.76 and root mean square error of prediction (RMSEP) of 969 mg L-1 HCO3-). When validated with new data, the NIRS method produced the best model (R-2 = 0.87 RMSEP = 1230 mg L-1 HCO3-). The NIRS sensor correlated better with new data (R-2 = 0.54). In conclusion, this study has developed new and improved algorithms for monitoring total alkalinity within anaerobic digestion systems which will facilitate real-time optimisation of methane production. (C) 2010 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据