3.8 Article

Multi loop snare technique for difficult inferior vena cava filter retrievals

期刊

CVIR ENDOVASCULAR
卷 1, 期 1, 页码 -

出版社

SPRINGERNATURE
DOI: 10.1186/s42155-018-0042-0

关键词

Pulmonary embolism; IVC filter; Venous intervention; Loop snare technique

向作者/读者索取更多资源

IntroductionUse of optional vena cava filters has steadily increased. In the majority of cases removal is successful using standard techniques. In cases of tilting and migration of the filter however, more advanced techniques are necessary. The loop-snare technique has been described for such cases. Difficulties arise when the loop starts to slip around the legs and arms of the filter.New techniqueWe present an improved loop-snare technique which allows to retrieve IVC filters when the simple loop-snare technique fails. We used additional loops, in one case one additional loop in another case two additional loops around the filter tip which allowed successful retrieval. The additional loops were created with a reversed shaped catheter. All guidewires were then engaged with a snare and pulled into a large sheath. The additional loops stabilize the tip and the filter can be pulled into the sheath.ConclusionThe multiple-loop-snare technique is a refinement of the previously described single loop-snare technique and can be used when one loop fails.