4.5 Article

Defining the Limits of Single-Molecule FRET Resolution in TIRF Microscopy

期刊

BIOPHYSICAL JOURNAL
卷 99, 期 9, 页码 3102-3111

出版社

CELL PRESS
DOI: 10.1016/j.bpj.2010.09.005

关键词

-

资金

  1. UK Bionanotechnology Informatics Research Center [GR/R45659/01]
  2. Engineering and Physical Sciences Research Council [EP/D058775]
  3. Biotechnology and Biological Sciences Research Council [BB/H0179SX/1]
  4. European Community [HEALTH-F4-2008-201418]
  5. German National Academic Foundation
  6. SAP
  7. MathWorks
  8. Wellcome Trust
  9. BBSRC [BB/H01795X/1] Funding Source: UKRI
  10. Biotechnology and Biological Sciences Research Council [BB/H01795X/1] Funding Source: researchfish

向作者/读者索取更多资源

Single-molecule FRET (smFRET) has long been used as a molecular ruler for the study of biology on the nanoscale (similar to 2-10 nm); smFRET in total-internal reflection fluorescence (TIRF) Forster resonance energy transfer (TIRF-FRET) microscopy allows multiple biomolecules to be simultaneously studied with high temporal and spatial resolution. To operate at the limits of resolution of the technique, it is essential to investigate and rigorously quantify the major sources of noise and error; we used theoretical predictions, simulations, advanced image analysis, and detailed characterization of DNA standards to quantify the limits of TIRF-FRET resolution. We present a theoretical description of the major sources of noise, which was in excellent agreement with results for short-timescale smFRET measurements (<200 ms) on individual molecules (as opposed to measurements on an ensemble of single molecules). For longer timescales (>200 ms) on individual molecules, and for FRET distributions obtained from an ensemble of single molecules, we observed significant broadening beyond theoretical predictions; we investigated the causes of this broadening. For measurements on individual molecules, analysis of the experimental noise allows us to predict a maximum resolution of a FRET change of 0.08 with 20-ms temporal resolution, sufficient to directly resolve distance differences equivalent to one DNA basepair separation (0.34 nm). For measurements on ensembles of single molecules, we demonstrate resolution of distance differences of one basepair with 1000-ms temporal resolution, and differences of two basepairs with 80-ms temporal resolution. Our work paves the way for ultra-high-resolution TIRF-FRET studies on many biomolecules, including DNA processing machinery (DNA and RNA polymerases, helicases, etc.), the mechanisms of which are often characterized by distance changes on the scale of one DNA basepair.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据