4.5 Article

A Method Improving the Accuracy of Fluorescence Recovery after Photobleaching Analysis

期刊

BIOPHYSICAL JOURNAL
卷 95, 期 11, 页码 5334-5348

出版社

CELL PRESS
DOI: 10.1529/biophysj.108.134874

关键词

-

资金

  1. Swedish Research Council for Engineering Sciences [2005-3140]

向作者/读者索取更多资源

Fluorescence recovery after photobleaching has been an established technique of quantifying the mobility of molecular species in cells and cell membranes for more than 30 years. However, under nonideal experimental conditions, the current methods of analysis still suffer from occasional problems; for example, when the signal/noise ratio is low, when there are temporal fluctuations in the illumination, or when there is bleaching during the recovery process. We here present a method of analysis that overcomes these problems, yielding accurate results even under nonideal experimental conditions. The method is based on circular averaging of each image, followed by spatial frequency analysis of the averaged radial data, and requires no prior knowledge of the shape of the bleached area. The method was validated using both simulated and experimental fluorescence recovery after photobleaching data, illustrating that the diffusion coefficient of a single diffusing component can be determined to within similar to 1%, even for small signal levels (100 photon counts), and that at typical signal levels (5000 photon counts) a system with two diffusion coefficients can be analyzed with < 10% error.