4.8 Article

Sandwich-type electrochemical aptasensor based on Au-modified conductive octahedral carbon architecture and snowflake-like PtCuNi for the sensitive detection of cardiac troponin I

期刊

BIOSENSORS & BIOELECTRONICS
卷 212, 期 -, 页码 -

出版社

ELSEVIER ADVANCED TECHNOLOGY
DOI: 10.1016/j.bios.2022.114431

关键词

Cardiac troponin I; Conductive carbon; Snowflake PtCuNi; Electrochemical aptasensor

资金

  1. Science and Technology Commission of Shanghai Municipality (STCSM) [20520712500, 20392002300]
  2. Fundamental Research Funds for the Central Universities [50321102117022]

向作者/读者索取更多资源

In this study, a sensitive sandwich-type cTnI electrochemical aptasensor was developed, showing excellent performance such as a wide linear range, ultra-low detection limit, good selectivity, stability, and recovery rate.
The cardiac troponin I (cTnI) detection is increasingly significant given its promising value in the clinical acute myocardial infarction diagnosis. Here a sensitive sandwich-type cTnI electrochemical aptasensor was developed by using zirconium-carbon loaded with Au (Au/Zr-C) as electrode-modified material and snowflake-like PtCuNi catalyst as label material. The Au/Zr-C was prepared from a carbonation process and a reduction step. The PtCuNi was synthesized by a one-pot hydrothermal reaction. On the one hand, due to its many merits of large effective area, rich pores, high degree of graphitization, the assistance of Au, the Au/Zr-C exhibited remarkable electronic conductivity but low catalytical capacity, thus improving the electrochemical property but lowing the background signal of electrode. On the other hand, because of its accessible active sites of the special snowflake-like structure and the synergy of three elements, the PtCuNi catalyst presented excellent catalytic activity and improved stability compared to binary alloy. The recognition reactions were achieved by stepwise incubation of aptamer 1, cTnI, and aptamer 2-PtCuNi (denoted as Apt2-label) on the Au/Zr-C-modified electrode. The electrocatalytic signals of the immobilized Apt2-label towards the H2O2 reduction were recorded in all tests for cTnI analysis. Consequently, this cTnI aptasensor exhibited excellent performance involving a wide linear range of 100 ng mL-1 to 0.01 pg mL(-1) with a detection limit of 1.24 x 10(-3) pg mL(-1) (S/N = 3), good selectivity, satisfying reproducibility, outstanding stability, and good recovery.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据