4.6 Article

Experimental investigation of a two-phase ejector installed into the refrigeration system for performance enhancement

期刊

ENERGY REPORTS
卷 8, 期 -, 页码 7263-7273

出版社

ELSEVIER
DOI: 10.1016/j.egyr.2022.05.236

关键词

Two-phase ejector; Ejector-expansion refrigeration; Expansion work recovery

资金

  1. King Mongkut?s University of Technology North Bangkok, Thailand [KMUTNB-64-KNOW-28]

向作者/读者索取更多资源

This paper experimentally investigates the performance enhancement of a two-phase ejector installed in a refrigeration system, comparing it with a conventional vapour-compression refrigeration system. Results show that the ejector-expansion refrigeration system (EERS) outperforms the vapor-compression refrigeration system (VCRS) when the expansion pressure ratio is sufficiently large, leading to improved system COP and compressor longevity.
In this paper, the performance enhancement of the two-phase ejector installed into the refrigeration system called an ejector-expansion refrigeration system (EERS) is investigated experimentally. A comparative performance of an ejector expansion refrigeration system (EERS) with a conventional vapour-compression refrigeration (VCRS) system is proposed. The main purpose is to demonstrate the ability to mitigate the throttling loss or to demonstrate the expansion work recovery in which the theoretical work is limited. The experimental test bench which can be operated with both VCRS and EERS is designed and built for investigations. It is designed to produce chilled water under various cooling loads which allows it to produce the desired cooling temperature for performance assessment. The condenser is cooled by the cooling water whose temperature can be controlled precisely. The test results indicate that the EERS gives better performance over the VCRS when the expansion pressure ratio must be large enough. Therefore, there is limitation of using the EERS for the expansion work recovery. The system COP can be increased by 5.3-12.7% when the cooling temperature is decreased from 12 to 2 degrees C. The pressure lift effect of the two-phase ejector causes a reduction in the compressor's pressure ratio which results in a lower specific work and the refrigerant discharge temperature. This yields a longer life-time of the compressor and better lubrication. It is also found that the working condition has a significant impact on the ability to enhance the system performance of the two-phase ejector installed into the refrigeration system. (c) 2022 The Author(s). Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据