Optimizing air conditioning systems by considering the grades of sensible and latent heat loads

期刊

APPLIED ENERGY
卷 322, 期 -, 页码 -

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.apenergy.2022.119458

关键词

Air treatment process; Load grade; Air conditioning; Liquid desiccant; Natural energy

资金

  1. National Natural Science Foundation of China [51521005]
  2. Key Laboratory of Eco Planning & Green Building, Ministry of Education (Tsinghua University) , Beijing, China

向作者/读者索取更多资源

Traditional air conditioning systems have low efficiency due to uniform treatment of all heat loads. A new method of designing air conditioning systems has been proposed to improve energy utilization, reduce energy consumption of electric heat pump systems, and enhance the use of natural and waste cooling and heating sources.
Traditional air conditioning systems uniformly treat all the sensible and latent heat loads of buildings by the lowest temperature chilled water, resulting in low efficiencies. Previous researchers proposed the temperature grades of staged loads and various energies, and the systems operate efficiently after being designed by grade matching. However, the method includes latent heat load with sensible heat load as the corresponding temperature grade; thus, the energy efficiency of the system designed can still be further improved. The latent heat systems have been experimentally improved, but the extent of applying appropriate humidity sinks and cooling and heating sources is unclear, and they are not comprehensively designed with sensible heat systems in the entire air conditioning systems. In this study, the humidity grade for the latent heat load and humidity sink is defined. A method for converting humidity grade to temperature grade is developed to obtain the potential of utilizing different humidity sinks, and cooling and heating sources in both sensible and latent load treatments. A grade-matching method is proposed to realize a more energy-efficient air conditioning system. A case study of an office building is used to demonstrate the method. The system designed using the proposed method improves energy-saving rates for heat pumps by 34.0% and 11.2% compared with the typical system (where latent and sensible heat subsystems are separately designed) and the system designed by the previous method (where the air treatments are limited to condensation dehumidification), respectively. This method is conducive to the more reasonable utilization of natural and waste cooling and heating sources for air treatment, and it reduces the capacities and energy consumptions of electric heat pump systems, resulting in significant energy savings.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据