4.2 Article

Detection by ELISA of low transferrin levels in bronchoalveolar secretions of preterm infants

期刊

JOURNAL OF IMMUNOLOGICAL METHODS
卷 233, 期 1-2, 页码 41-45

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/S0022-1759(99)00191-X

关键词

transferrin; ELISA; BAS; preterm infants; iron-binding protein

向作者/读者索取更多资源

Transferrin levels in bronchoalveolar secretions (BAS) are very low compared to serum levels in humans. For the exact measurement of transferrin concentrations in BAS a very sensitive assay was developed as a double sandwich enzyme immunoassay using the combination of a polyclonal and a monoclonal antibody against human transferrin. The measurable range of the assay was 1.5 to 100 ng/ml of human transferrin. The lowest measurable value was 0.84 ng/ml and the sensitivity of the assay was 0.88 ng/ml. The coefficient of variation was 14.1% for 25 ng/ml (intra-assay) and 11-20% (inter-assay). The levels measured in 123 samples of BAS of preterm infants ranged between 0.03 and 8.93 (mu g/mu g secretory component (SC)). The determination of transferrin in BAS of preterm infants is helpful in determining oxidative damage, e.g. the availability of free iron, in the neonatal lung. The transferrin concentration in BAS of neonates who recovered from respiratory distress syndrome (RDS) in the first six days of life was 0.48 compared to 0.52 ((mu g/mu g SC), median range) for infants who developed chronic lung disease. (C) 2000 Elsevier Science B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.2
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据