4.2 Article

Automated high throughput human CYP isoform activity assay using SPE-LC/MS method: application in CYP inhibition evaluation

期刊

XENOBIOTICA
卷 30, 期 2, 页码 141-154

出版社

TAYLOR & FRANCIS LTD
DOI: 10.1080/004982500237749

关键词

-

向作者/读者索取更多资源

1. A high throughput screening (HTS) method for the evaluation of the seven major human hepatic CYP isoform activities was developed on a 96-well format, with automation. The method utilized pooled human liver microsomes and seven probe substrates, generic conditions for incubation, reaction termination and metabolite extraction with solid phase extraction (SPE) plates. Metabolites from the seven reactions were pooled and quantified using a generic liquid chromatography and tandem mass spectrometry (LCMS/MS) method. 2. The HTS method was validated based on K-m values obtained, which were in agreement with literature data. 3. The isoform inhibition profiles of ketoconazole, quinidine, sulfaphenazole, tranylcypromine, alpha-naphthoflavone, and 4-methylpyrazole against CYPs 3A4, 2D6, 2C9, 2A6 (and 2C19), 1A2 and 2E1, respectively, were obtained by this HTS method. Graphically obtained IC(50)values are in agreement with literature reported values. 4. The HTS method represents a significant efficiency and selectivity improvement over traditional methods, and can be used for CYP inhibition assay and can be extended for liver activity profiling.