期刊
BIOMEDICAL MICRODEVICES
卷 12, 期 1, 页码 35-40出版社
SPRINGER
DOI: 10.1007/s10544-009-9355-z
关键词
Cell electroporation; Microfluidics; Hydrodynamic focusing
资金
- National Basic Research Program [2007CB935602]
- NSFC [90607004, 10672005, 10872008, 10634010, 10704002]
Microfluidics-based cell electroporation has many advantages in delivering small molecules into cells. In this study, hydrodynamic focusing of fluids with different conductivities has been used for high through-put cell electroporation at low voltage (<3 V) of continuous direct current (dc) power. Simulation results showed that an input voltage of only 1.5 V could generate an electric field intensity of about 1.17 kV cm(-1) across the cell suspension flow in the squeezed area. The electropermeation of yeast cell was observed, showing a permeabilization percentage up to 70%.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐