4.8 Article

The effect of a polyurethane coating incorporating both a thrombin inhibitor and nitric oxide on hemocompatibility in extracorporeal circulation

期刊

BIOMATERIALS
卷 35, 期 26, 页码 7271-7285

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.biomaterials.2014.05.036

关键词

Argatroban; Direct thrombin inhibition; Nitric oxide releasing polymer; Thrombogenicity; Hexane methylene diisocyanate (HMDI); Polyethylene glycol (PEG)

资金

  1. National Institutes of Health [R21EB016236, K25HL111213]
  2. Federal Drug Administration [2P50FD003787-03]

向作者/读者索取更多资源

Nitric oxide (NO) releasing (NORel) materials have been extensively investigated to create localized increases in NO concentration by the proton driven diazeniumdiolate-containing polymer coatings and demonstrated to improve extracorporeal circulation (ECC) hemocompatibility. In this work, the NORel polymeric coating composed of a diazeniumdiolated dibutylhexanediamine (DBHD-N2O2)-containing hydrophobic Elast-eon (TM) (E2As) polyurethane was combined with a direct thrombin inhibitor, argatroban (AG), and evaluated in a 4 h rabbit thrombogenicity model without systemic anticoagulation. In addition, the immobilizing of argatroban to E2As polymer was achieved by either a polyethylene glycol-containing (PEGDI) or hexane methylene (HMDI) diisocyanate linker. The combined polymer film was coated on the inner walls of ECC circuits to yield significantly reduced ECC thrombus formation compared to argatroban alone ECC control after 4 h blood exposure (0.6 +/- 0.1 AG/HMDI/NORel vs 1.7 +/- 0.2 cm(2) AG/HMDI control). Platelet count (2.8 +/- 0.3 AG/HMDI/NORel vs 1.9 +/- 0.1 x 10(8)/ml AG/HMDI control) and plasma fibrinogen levels were preserved after 4 h blood exposure with both the NORel/argatroban combination and the AG/HMDI control group compared to baseline. Platelet function as measured by aggregometry remained near normal in both the AG/HMDI/NORel (63 +/- 5%) and AG/HMDI control (58 +/- 7%) groups after 3 h compared to baseline (77 +/- 1%). Platelet P-selectin mean fluorescence intensity (MFI) as measured by flow cytometry also remained near baseline levels after 4 h on ECC to ex vivo collagen stimulation (16 +/- 3 AG/HMDI/NORel vs 11 +/- 2 MFI baseline). These results suggest that the combined AG/HMDI/NORel polymer coating preserves platelets in blood exposure to ECCs to a better degree than AG/PEGDI/NORel, NORel alone or AG alone. These combined antithrombin, NO-mediated antiplatelet effects were shown to improve thromboresistance of the AG/HMDI/NORel polymer-coated ECCs and move potential nonthrombogenic polymers closer to mimicking vascular endothelium. (C) 2014 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据