4.7 Article

Polyglycerol based coatings to reduce non-specific protein adsorption in sample vials and on SPR sensors

期刊

ANALYTICA CHIMICA ACTA
卷 867, 期 -, 页码 47-55

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.aca.2015.01.048

关键词

QCM; SPR; Biosensor; Nonspecific protein adsorption; Molecular diagnostics

资金

  1. Helmholtz Virtual Institute
  2. Poly4Bio (BMBF)
  3. Canada Research Chair (CRC) in Molecular Pharmacology
  4. Canada Foundation for Innovation (CFI)
  5. [SFB 765]

向作者/读者索取更多资源

Coatings based on dendritic polyglycerol (dPG) were investigated for their use to control nonspecific protein adsorption in an assay targeted to analyze concentrations of a specific protein. We demonstrate that coating of the sample vial with dPG can significantly increase the recovery of an antibody after incubation. First, we determine the concentration dependent loss of an antibody due to nonspecific adsorption to glass via quartz crystal microbalance (QCM). Complementary to the QCM measurements, we applied the same antibody as analyte in an surface plasmon resonance (SPR) assay to determine the loss of analyte due to nonspecific adsorption to the sample vial. For this purpose, we used two different coatings based on dPG. For the first coating, which served as a matrix for the SPR sensor, carboxyl groups were incorporated into dPG as well as a dithiolane moiety enabling covalent immobilization to the gold sensor surface. This SPR-matrix exhibited excellent protein resistant properties and allowed the immobilization of amyloid peptides via amide bond formation. The second coating which was intended to prevent nonspecific adsorption to glass vials comprised a silyl moiety that allowed covalent grafting to glass. For demonstrating the impact of the vial coating on the accuracy of an SPR assay, we immobilized amyloid beta (A beta) 1-40 and used an anti-A beta 1-40 antibody as analyte. Alternate injection of analyte into the flowcell of the SPR device from uncoated and coated vials, respectively gave us the relative signal loss (1 - RUuncoated/RUcoated) caused by the nonspecific adsorption. We found that the relative signal loss increases with decreasing analyte concentration. The SPR data correlate well with concentration dependent non-specific adsorption experiments of the analyte to glass surfaces performed with QCM. Our measurements showthat rendering both the sample vial and the sensor surface is crucial for accurate results in protein assays. (c) 2015 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据