4.0 Article

Indoor and outdoor formaldehyde concentrations in homes in residential areas in Greater Cairo

期刊

JOURNAL OF ENVIRONMENTAL MONITORING
卷 2, 期 2, 页码 123-126

出版社

ROYAL SOC CHEMISTRY
DOI: 10.1039/a908756g

关键词

-

向作者/读者索取更多资源

Indoor and outdoor measurements of formaldehyde were conducted at seven flats located in residential areas in Greater Cairo, during spring and summer seasons 1999. The mean daytime formaldehyde concentrations in kitchens, bedrooms and living rooms were 89, 100 and 100 ppb, respectively, in the seven flats. Significant positive correlations were found between the concentrations of formaldehyde found in these three rooms. On the other hand, no significant differences were found between the mean formaldehyde concentrations in these three rooms. The maximum mean concentration of formaldehyde (147 ppb) was recorded in a new flat, while the minimum concentration (43 ppb) was observed in an old flat. The maximum hourly and daytime concentrations were 350 and 225 ppb, respectively. Air temperature, relative humidity and the age of the flat are factors affecting the emission and concentration of formaldehyde. The maximum indoor and outdoor formaldehyde concentrations were recorded during the summer season. During the spring, 38% of the samples indicated that the concentration of formaldehyde in the seven flats exceeded 0.1 ppm, the American Society of Heating, Refrigerating, and Air Conditioning Engineers' (ASHRAE) standard; in the summer, this figure increased to 53%.