4.8 Article

A photopolymerized antimicrobial hydrogel coating derived from epsilon-poly-L-lysine

期刊

BIOMATERIALS
卷 32, 期 11, 页码 2704-2712

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.biomaterials.2010.12.040

关键词

Antimicrobial peptide; Contact-active coating; Hydrogel; Hemolysis; Epsilon-poly-L-lysine; Graft

资金

  1. Menicon Company
  2. Nanyang Technological University

向作者/读者索取更多资源

Hydrogels made from epsilon-poly-L-lysine-graft-methacrylamide (EPL-MA) have been found to have impressive wide spectrum antimicrobial activity against both bacteria (specifically Escherichia colt, Pseudomonas aeruginosa, Serratia marcescens and Staphylococcus aureus) and fungi (specifically Candida albicans and Fusarium solani). The EPL-MA hydrogel also possesses in vitro biocompatibility and EPL-MA solution is relatively non-hemolytic: the concentration needed for onset of human red blood cell (hRBC) hemolysis is 12,500 mu g/mL so that the selectivity for the pathogenic microorganisms over hRBCs is 230-1560. Further, EPL-MA hydrogel can be conveniently ultraviolet-immobilized onto plasma-treated plastic surfaces to form thin highly adherent antimicrobial hydrogel coatings for medical devices and implants. (C) 2011 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据