4.5 Article

Effect of dentin desensitizers and cementing agents on retention of full crowns using standardized crown preparations

期刊

JOURNAL OF PROSTHETIC DENTISTRY
卷 83, 期 4, 页码 459-465

出版社

MOSBY-YEAR BOOK INC
DOI: 10.1016/S0022-3913(00)70042-4

关键词

-

向作者/读者索取更多资源

Statement of problem. Past research has not controlled preparation surface area when examining the influence of dentin desensitizers on the retentive strength of cemented cast crowns, leading to inconsistent results. Purpose. This research controlled crown preparation surface area and evaluated. the the effect of various dentin desensitizers and conventional cementing agents on the in vitro retentive strength of cast crowns. Methods and material. Freshly extracted human molars were prepared for a standardized crown preparation (26 degrees total convergence, 4 mm axial height) with a custom-made pantograph. Dentin desensitizers included none (control), a polymerizable material (All-Bond 2), and a nonpolymerizable desensitizer (Gluma Desensitizer). Cementing agents included zinc phosphate (Fleck's), glass ionomer (Ketac-Cem) resin-modified glass ionomer (Fuji II), and resin cement (Panavia 21). Twelve teeth were prepared for each test condition (144 teeth total). Individual castings were made from a base metal alloy (Rexillium III). Crowns were removed after storage at 26 degrees C for 48 hours at 100% relative: humidity! using a universal testing machine at a crosshead speed of 1.27 mm/min. The proportion of cement retained on the tooth and casting after debonding nas quantified according to treatment. Statistical treatment included 1- and 2-way ANOVAs, followed by the Tukey-Kramer post hoc test at a preset alpha of 0.05. Results. Resin cement exhibited the highest retentive strength and all dentin treatments resulted in significantly different retentive values (All-Bond 2 (5.68 +/- 0.70 MPa) > control (4.67 +/- 0.48 MPa) > Gluma. (4.12 +/- 0.37 MPa)). Retention of resin-modified glass ionomer was between thr resin cement and glass ionomer groups: All-Bond 2 (3.46 +/- 0.26 MPa) > Gluma (2.81 +/- 0.15 MPa) = control (2.96 +/- 0.18 MPa). Conventional glass ionomer values were between those of Fuji Plus and zinc phosphate groups: All Bond 2 (2.23 +/- 0.20 MPa) = control (2.36 +/- 0.20 MPa) > Gluma (1.98 +/- 0.23 MPa). Zinc phosphate had the: lowest retention values: control (1.68 +/- 0.08 MPa) > Gluma (0.81 +/- 0.11 MPa) > All-Bond 2 (0.67 +/- 0.14 MPa). The majority! of cement was retained on the debonded tooth surface versus thr casting, with the excetption of zinc phosphate: when: used with dentin pretreatments. Conclusion. Controlled crown surface areas reduced the variation in strength values permitting high discrimination among retention values of desensitizer/cement combinations. In all but 1 combination, Gluma desensitizer significantly! decreased crown retention. With resin cement and resin-modified glass ionomer, use of All-Bond 2 desensitizer significantly increased crown retention values.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据