4.8 Article

3C strategy for inverters in parallel operation achieving an equal current distribution

期刊

IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS
卷 47, 期 2, 页码 273-281

出版社

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/41.836342

关键词

circular chain control; equal current distribution; multimodule inverter

向作者/读者索取更多资源

A circular chain control (3C) strategy for inverters in parallel operation is presented in the paper, In the proposed inverter system, all the modules have the same circuit configuration, and each module includes an inner current loop and an outer voltage loop control. A proportional-integral controller is adopted as the inner current loop controller to expedite the dynamic response, while an H-infinity robust controller is adopted to reach the robustness of the multimodule inverter system and to reduce possible interactive effects among inverters. With the 3C strategy, the modules are in circular chain connection and each module has an inner current loop control to track the inductor current of its previous module, achieving an equal current distribution. Simulation results of two-module and a three-module inverter systems with different kinds of loads and with modular discrepancy have demonstrated the feasibility of the proposed control scheme, Hardware measurements are also presented to verify the theoretical discussion.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据