4.1 Article

Towards optimal recording and analysis of the mismatch negativity

期刊

AUDIOLOGY AND NEURO-OTOLOGY
卷 5, 期 3-4, 页码 235-246

出版社

KARGER
DOI: 10.1159/000013885

关键词

mismatch negativity (MMN); auditory event-related potential (ERP) reliability; optimal effective paradigm and analysis

向作者/读者索取更多资源

In this paper, the conceptual and practical issues related to the measurement of mismatch negativity (MMN) are discussed from the viewpoint of cost-efficiency. First, various criteria for efficiency or optimality of measurements are described, including reliability and signal-to-noise ratio. Then a critical look is taken at some currently used concepts and data analysis methods. Practical guidelines for the measurement and analysis of MMN are given, complementing the earlier reviews on the subject. Finally, reliability studies on MMN are critically reviewed. Copyright (C) 2000 S. Karger AG, Basel.