4.7 Article

Gold nanoparticle-antibody conjugates for specific extraction and subsequent analysis by liquid chromatography-tandem mass spectrometry of malondialdehyde-modified low density lipoprotein as biomarker for cardiovascular risk

期刊

ANALYTICA CHIMICA ACTA
卷 857, 期 -, 页码 53-63

出版社

ELSEVIER
DOI: 10.1016/j.aca.2014.12.024

关键词

Gold nanoparticle; Antibody bioconjugate; Oxidized low-density lipoprotein; Malondialdehyde-modified low-density lipoprotein; High-performance liquid chromatography-tandem mass spectrometry; Oxidative stress

资金

  1. NanoMALDI project by the Austrian BMVIT via the Austrian Nano-Initiative [828701]
  2. NanoMALDI project by the Austrian BMVIT via the MNT-ERA.NET [828701]

向作者/读者索取更多资源

Oxidized low-density lipoproteins (OxLDLs) like malondialdehyde-modified low-density lipoprotein (MDA-LDL) play a major role in atherosclerosis and have been proposed as useful biomarkers for oxidative stress. In this study, gold-nanoparticles (GNPs) were functionalized via distinct chemistries with anti-MDA-LDL antibodies (Abs) for selective recognition and capture of MDA-LDL from biologicalmatrices. The study focused on optimization of binding affinities and saturation capacities of the antiMDA-LDL-Ab-GNP bioconjugate by exploring distinct random and oriented immobilization approaches, such as (i) direct adsorptive attachment of Abs on the GNP surface, (ii) covalent bonding by amide coupling ofAbs to carboxy-terminated-pegylated GNPs, (iii) oriented immobilization via oxidized carbohydrate moiety of the Ab on hydrazide-derivatized GNPs and (iv) cysteine-tagged protein A (cProtA)-bonded GNPs. Depending on immobilization chemistry, up to 3 antibodies per GNP could be immobilized as determined by ELISA. The highest binding capacity was achieved with the GNP-cProtA-Ab bioconjugate which yielded a saturation capacity of 2.24 +/- 0.04 mu gmL(-1) GNP suspension for MDA-LDL with an affinity K-d of 5.25 +/- 0.11 x 10(-10) M. The GNP-cProtA-antiMDA-LDL bioconjugate revealed high specificity for MDA-LDL over copper(II)oxidized LDL as well as native human LDL. This clearly demonstrates the usefulness of the new GNP-Ab bioconjugates for specific extraction of MDA-LDL from plasma samples as biomarkers of oxidative stress. Their combination as specific immunoextraction nanomaterials with analysis by LC-MS/MS allows sensitive and selective detection of MDA-LDL in complex samples. (C) 2014 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据