4.6 Article

Effect of short- and long-term storage on human serum and recombinant apolipoprotein E concentration

期刊

CLINICAL CHEMISTRY AND LABORATORY MEDICINE
卷 38, 期 6, 页码 525-528

出版社

WALTER DE GRUYTER & CO
DOI: 10.1515/CCLM.2000.077

关键词

apolipoprotein E concentration; storage; freeze-thaw; immunoturbidimetry; apo E isoforms

向作者/读者索取更多资源

In order to assess the short- and long-term stability of apolipoprotein (apo) E concentration in serum, we compared the apo E concentrations measured in fresh human serum samples with those determined after storage at +4 degrees C, -20 degrees C or -80 degrees C. The serum apo E concentration was measured by immunoturbidimetry using an anti-human apo E polyclonal antibody from goats. One week storage at +4 degrees C did not significantly affect the serum apo E concentration. At -20 degrees C or -80 degrees C no significant change in apo E concentration occurred during up to three months of storage. Moreover, the concentration of apo E was not modified after long-term storage of serum samples kept at -196 degrees C in liquid nitrogen for up to four years. In addition, 15 freeze-thaw cycles, over a 3-week period, did not affect the apo E concentration in serum. A similar freeze-thaw procedure applied to purified human recombinant apo E showed that apo E2 isoform was the most stable in comparison with the apo E3 and apo E4 isoforms.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据