4.7 Article

Ultra high performance liquid chromatography coupled to tandem mass spectrometry determination of lipid peroxidation biomarkers in newborn serum samples

期刊

ANALYTICA CHIMICA ACTA
卷 886, 期 -, 页码 214-220

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.aca.2015.06.028

关键词

Isoprostanes; Liquid chromatography; Mass spectrometry; Serum; Newborn; Oxidative stress

资金

  1. Carmen & Severo Ochoa Grant (City Government
  2. Valencia)
  3. Health Institute Carlos III (Spanish Ministry of Economy and Competitiveness) [FIS PI14/0443, RD12/0026/0012]
  4. 'Sara Borrell' grant from the Health Institute Carlos III (Spanish Ministry of Economy and Competitiveness) [CD12/00667]
  5. Red de Salud Materno Infantil (SAMID)

向作者/读者索取更多资源

Byproducts of arachidonic (AA) and docosahexaenoic acid (DHA) oxidation are highly relevant for the study of free radical associated conditions in the perinatal period. Plasma metabolites can provide the clinician with a snapshot of the oxidant status of patients before and after specific clinical interventions (e.g.: supplementation with oxygen). We describe a new andreliable ultra-performance liquid mass spectrometry method to determine F2-isoprostanes and other byproducts (isoprostanes, isofurans, neuroprostanes, neurofurans) in newborn serum samples. Cord blood samples were obtained from severely depressed newborn infants (Apgar score 1 min < 3; arterial cord pH < 7.00), and aliquoted for serum determination and stored at -80 degrees C. AUHPLC-MS/MS method was employed. It has a series of technical advantages: simple sample treatment; reduced sample volume (100 mu L) which is essential for preterm neonates with low circulating blood volume, high throughput of sample analysis (96 samples in less than 24 h) and high selectivity for different isoprostanes isomers. Excellent sensitivity was achieved within limits of detection between 0.06 and 4.2 nmol L-1, which renders this method suitable to monitoranalyte concentration in newborn samples. The method's precision was satisfactory; with coefficients of variation around 5-12% (intra-day) and 7-17% (inter-day). The reliability of the described method was assessed by analysis of spiked serum samples obtaining recoveries between 70% and 120%. The proposed method has rendered suitable for serum determination for newborn babies at risk of oxygen free radical associated conditions. (C) 2015 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据