期刊
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE
卷 49, 期 4, 页码 621-626出版社
LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/00005373-200010000-00008
关键词
abdominal perfusion pressure; intra-abdominal pressure; intravesicular pressure; intra-abdominal hypertension; abdominal compartment syndrome; hemodynamic monitoring
Objective: To assess the clinical utility of abdominal perfusion pressure (mean arterial pressure minus intra-abdominal pressure) as both a resuscitative endpoint and predictor of survival in patients with intra-abdominal hypertension. Methods: 144 surgical patients treated for intra-abdominal hypertension between May 1997 and June 1999 were retrospectively reviewed. Multivariate logistic regression and receiver operating characteristic curve analysis of common physiologic variables and resuscitation endpoints were performed to determine the decision thresholds for each variable that predict patient survival. Results: Abdominal perfusion pressure was statistically superior to both mean arterial pressure and intravesicular pressure in predicting patient survival from intra-abdominal hypertension and abdominal compartment syndrome. Multiple regression analysis demonstrated that abdominal perfusion pressure was also superior to other common resuscitation endpoints, including arterial pH, base deficit, arterial lactate, and hourly urinary output. Conclusion: Abdominal perfusion pressure appears to be a clinically useful resuscitation endpoint and predictor of patient survival during treatment for intra-abdominal hypertension and abdominal compartment syndrome.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐