4.7 Article

Outcomes 15 years after valve replacement with a mechanical versus a bioprosthetic valve: Final report of the Veterans Affairs randomized trial

期刊

JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY
卷 36, 期 4, 页码 1152-1158

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/S0735-1097(00)00834-2

关键词

-

向作者/读者索取更多资源

OBJECTIVES The goal of this study was to compare long-term survival and valve-related complications between bioprosthetic and mechanical heart valves. BACKGROUND Different heart valves may have different patient outcomes. METHODS Five hundred seventy-five patients undergoing single aortic valve replacement (AVR) or mitral valve replacement (MVR) at 13 VA medical centers were randomized to receive a bioprosthetic or mechanical valve. RESULTS By survival analysis at 15 years, all cause mortality after AVR was lower with the mechanical valve versus bioprosthesis (66% vs. 79%, p = 0.02) but not after MVR. Primary valve failure occurred mainly in patients <65 years of age (bioprosthesis vs. mechanical, 26% vs. 0%, p < 0.001 for AVR and 44% vs. 4%, p = 0.0001 for MVR), and in patients greater than or equal to 65 years after AVR, primary valve failure in bioprosthesis versus mechanical valve was 9 +/- 6%, versus 0%, p = 0.16. Reoperation was significantly higher for bioprosthetic AVR (p = 0.004). Bleeding occurred more frequently in patients with mechanical valve. There were no statistically significant differences for other complications, including thromboembolism and all valve-related complications between the two randomized groups. CONCLUSIONS At 15 years, patients undergoing AVR had a better survival with a mechanical valve than with a bioprosthetic valve, largely because primary valve failure was virtually absent with mechanical valve. Primary valve failure was greater with bioprosthesis, both for AVR and MVR, and occurred at a much higher rate in those aged <65 years; in those aged greater than or equal to 65 years, primary valve failure after AVR was not significantly different between bioprosthesis and mechanical valve. Reoperation was more common for AVR with bioprosthesis. Thrombo-embolism rates were similar in the two valve prostheses, but bleeding was more common with a mechanical valve. (J Am Coil Cardiol 2000;36:1152-8) (C) 2000 by the American College of Cardiology.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据