4.3 Article

Methodologies for evaluating electromyographic field data in ergonomics

期刊

JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY
卷 10, 期 5, 页码 301-312

出版社

ELSEVIER SCI LTD
DOI: 10.1016/S1050-6411(00)00022-5

关键词

electromyography; dose; exposure; fatigue; musculoskeletal disorders; physical load

向作者/读者索取更多资源

Surface electromyography (SEMG) is an important tool for work load assessment in ergonomics. Several different approaches using amplitude as well as frequency parameters give fruitful information depending on question at issue in the laboratory as well as in field studies. One basic factor determining the choice of analysis method is whether the SEMG is interpreted as an indicator of forces/torques or pure muscular activation. Two methods for occupational SEMG data reduction representing two different approaches to SEMG applications in ergonomics, Exposure Variation Analysis (EVA), and Joint Analysis of EMG Spectrum and Amplitude (JASA), applied on the same SEMG recording from three muscles during urology surgeon work, have been compared. The EVA method categorised the three muscle recordings as too static with no EMG gaps while the JASA method identifies fatigue in two of the three recordings. The practical relevance of these findings is discussed. (C) 2000 Elsevier Science Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据