Cervical pedicle screws - Comparative accuracy of two insertion techniques

期刊

SPINE
卷 25, 期 20, 页码 2675-2681

出版社

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/00007632-200010150-00022

关键词

Abumi technique; cervical spine; pedicle; screw; stereotaxis

向作者/读者索取更多资源

Study Design. Independently assessed radiographic and anatomic comparison of device implantation methods. Objectives, To compare the relative accuracy of two techniques of inserting cervical pedicle screws. Summary of Background Data. In an attempt to define the anatomic risks of cervical pedicle screw insertion, image-guided stereotactic technology was shown to be superior to some other methods in vitro. Meanwhile,:in vivo experience with Abumi's technique of screw insertion has had few clinically relevant instances of screw malposition. There has been no direct comparison between current image-guided technology and Abumi's fluoroscopically assisted technique. Methods, The pedicles (C3-C7) of human cadaveric cervical spines were instrumented with 3.5-mm screws with either of two techniques. Cortical integrity and potential neurovascular injury were independently assessed by computed tomographic (CT) scans and anatomic dissection. A cortical breach was considered critical if the screw encroached on any vital structure. If any part of the screw violated the cortex of the pedicle but no vital structure was at risk for injury, the breach was classified as noncritical. Results. In Group I (StealthStation; Sofamor-Danek, Memphis, TN), 82% of screws were placed in the pedicle, and 18% had a critical breach. In Group II (Abumi technique), 88% of screws were placed in the pedicle, and 12% had a critical breach. No statistically significant differences were demonstrated between each group (P=0.59). Regarding pedicle dimensions and safety of insertion, a critical pedicle diameter of 4.5 mm was determined to be the size below which a critical breach was likely, but above which there was a significantly greater likelihood for safe screw placement, The most common structure injured in each group was the vertebral artery. Conclusions. The use of a computer-assisted image guidance system did not enhance safety or accuracy in placing pedicle screws compared with Abumi's technique. Both techniques have a noteworthy risk of injuring a critical structure if inserted into the pedicles with a diameter of less than 4.5 mm. Under laboratory conditions, pedicles with a diameter of more than 4.5 mm have a significantly greater likelihood of being safely instrumented by either technique. These data indicate that cervical pedicle screw placement is feasible, but it should be reserved for selected circumstances with clear indications and in the presence of suitable pedicle morphology.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据