Sol-gel-derived α2-K7P2W17VO62/graphite/organoceramic composite as the electrode material for a renewable amperometric hydrogen peroxide sensor

期刊

JOURNAL OF ELECTROANALYTICAL CHEMISTRY
卷 495, 期 1, 页码 51-56

出版社

ELSEVIER SCIENCE SA
DOI: 10.1016/S0022-0728(00)00371-5

关键词

sol-gel; composite; polyoxometalate; amperometric sensor; hydrogen peroxide

向作者/读者索取更多资源

The conductive alpha (2)-K7P2W17VO62/graphite/organoceramic composite was prepared by dispersing alpha (2)-K7P2W17VO62 and graphite powder in a propyltrimethoxysilane-based sol-gel solution; it was used as the electrode material for an amperometric hydrogen peroxide sensor. The modified electrode had a homogeneous mirror-like surface and showed well defined cyclic voltammograms. Square-wave voltammetry was employed to study the pH-dependent electrochemical behavior of c alpha (2)-K7P2W17VO62 doped in the graphite organoceramic matrix, and the experiment showed that both protons and sodium cations participated in the odor process. A hydrodynamic voltammetric experiment was performed to characterize the electrode as an amperometric sensor for the determination of hydrogen peroxide. The sensor can be renewed easily in a repeatable manner by a mechanical polishing step and has a long operational lifetime. (C) 2000 Elsevier Science B.V. All rights reserved.