4.8 Article

Increasing the number of analyzable peaks in comprehensive two dimensional separations through chemometrics

期刊

ANALYTICAL CHEMISTRY
卷 73, 期 3, 页码 675-683

出版社

AMER CHEMICAL SOC
DOI: 10.1021/ac0010025

关键词

-

向作者/读者索取更多资源

Comprehensive two-dimensional (2-D) separations are emerging as powerful tools for the analysis of complex samples. The substantially larger peak capacity for a given length of time relative to 1-D separations is a well-known benefit of comprehensive 2-D separation methods. Unfortunately, with complex samples, the probability of peak overlap in 2-D separations is still quite high. This is especially true if one desires to speed up the analysis by reducing the run time and, thus, by reducing the resolving power along the first dimension separation. Chemometric methods hold considerable promise to overcome the limitations brought upon by the likelihood of peak overlap. Thus, chemometric methods should be able to effectively extend the resolving power of 2-D separation methods, In this paper, the theoretical enhancement provided by application of the generalized rank annihilation method (GRAM) for the analysis of unresolved peaks in comprehensive 2-D separations is carefully modeled and critically evaluated. First, Monte Carlo simulations are used to determine the-conditions where the use of GRAM results in the successful analysis of unresolved peaks. A wide range of experimental conditions and performance criteria are modeled, typical to many available 2-D separation methods, including alnalyte/interference peak height ratio, first- and second-dimension resolutions, signal-to noise ratio, injection volume reproducibility, and run-to-run retention time reproducibility, Essentially, a wide range of experimental conditions and performance criteria are found to provide reliable data amenable to GRAM analysis. The information gleaned from this first set of simulations is then used in conjunction with Monte Carlo simulations of comprehensive 2-D separations. For these simulated 2-D separations, the total number of analyzable peaks when using GRAM was determined and found to be substantially better than using only traditional quantitative methods such as peak integration or height, For example, it was determined that the use of GRAM increases the average number of analyzable peaks by a factor of 2 for 2-D separations in which the peak capacity is 67% occupied by randomly distributed peaks. The results of the studies are general, and the use of GRAM should increase the number of analyzable peaks for all forms of comprehensive 2-D separations.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据