4.7 Article

A valve-less diffuser micropump for microfluidic analytical systems

期刊

SENSORS AND ACTUATORS B-CHEMICAL
卷 72, 期 3, 页码 259-265

出版社

ELSEVIER SCIENCE SA
DOI: 10.1016/S0925-4005(00)00644-4

关键词

valve-less micropump; highly viscous liquids; bead handling; living cells

向作者/读者索取更多资源

The suitability of valve-less micropumps in biochemistry has been shown. Fluids encountered in various biochemical methods that are problematic for other micropumps have been pumped with good performance. The pump is fabricated as a silicon-glass stack with a new process involving three subsequent deep reactive ion etching steps. Some of the main advantages of the valve-less diffuser pump are the absence of moving parts (excluding the pump diaphragm), the uncomplicated planar design, and high pump performance in terms of pressure head and flow rare. In addition, the micropump is self-priming and insensitive to particles and bubbles present in the pumped media. The results show that the valve-less micropump successfully pumps fluids within the viscosity range of 0.001-0.9 N s/m(2). The micropump is not sensitive to the density, ionic strength, or pH of the pumped media. Effective pumping of solutions containing beads of different sizes was also demonstrated. Living cells were pumped without inducing cell damage and no cell adhesion within the pump chamber was found. No valve-less micropump has previously been reported to pump such a wide variety of fluids. (C) 2001 Elsevier Science B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据