4.6 Article

Characteristics of Pt/Nafion® electrodes prepared by a Takenata-Torikai method in sensing hydrogen

期刊

MATERIALS CHEMISTRY AND PHYSICS
卷 69, 期 1-3, 页码 267-273

出版社

ELSEVIER SCIENCE SA
DOI: 10.1016/S0254-0584(00)00460-0

关键词

Takenata-Torikai method; Pt/Nafion (R); sensitivity; response and recovery time; hydrogen sensor

向作者/读者索取更多资源

The influences of reductant concentration and Pr loading on the response and the recovery time and the sensitivity of the Pt/Nafion(R) electrodes prepared by a Takenata-Torikai method in detecting hydrogen were investigated in this study. The sensitivities of Pt/Nafion(R) electrodes prepared in 0.06 N NaBH4 increase non-linearly from 0.0332 to 0.152 muA/cm(2) ppm with increasing Pt loadings from 2.59 to 7.76 mg/cm(2) in the H-2 concentration range of 0-152542 ppm. However, the sensitivities per unit Pt loading show a maximum at Pt loading of 5.20 mg/cm(2). Meanwhile, the Pt/Nafion(R) electrodes with Pt loading of 7.76 mg/cm(2) obtained at 0.06 N NaBH4, show the fastest response and recovery speed in sensing hydrogen. Generally, both the response and the recovery time decrease with an increasing of the hydrogen concentration. A sensing model was also proposed to illustrate the sensing phenomenon. (C) 2001 Elsevier Science B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据