Load-Sharing Between Anterior and Posterior Elements in a Lumbar Motion Segment Implanted With an Artificial Disc

期刊

SPINE
卷 26, 期 6, 页码 E122-E129

出版社

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/00007632-200103150-00004

关键词

artificial disc; biomechanics; facets; finite element model; lumbar spine

资金

  1. Sofamor Danek Group, Memphis, TN
  2. Iowa Spine Research Foundation, Iowa City, IA
  3. Whitaker Foundation, Rosslyn, VA

向作者/读者索取更多资源

Study Design. A nonlinear three-dimensional finite element model of the osteoligamentous L3-L4 motion segment was used to predict changes in posterior element loads as a function of disc implantation and associated surgical procedures. Objectives. To evaluate the effects of disc implantation on the biomechanics of the posterior spinal elements (including the facet joints, pedicles, and lamina) and on the vertebral bodies. Summary of Background Data. Although several artificial disc designs have been used clinically, biomechanical data-particularly the change in loads in the posterior elements after disc implantation-are sparse. Methods. A previously validated intact finite element model was implanted with a ball-and-cup-type artificial disc model via an anterior approach. The implanted model predictions were compared with in vitro data. To study surgical variables, small and large windows were cut into the anulus, and the implant was placed anteriorly and posteriorly within the disc space. The anterior longitudinal ligament was also restored. Models were subjected to either 800 N axial compression force alone or to a combination of 10 N-m flexion-extension moment and 400 N axial preload. Implanted model predictions were compared with those of the intact model. Results. Facet loads were more sensitive to the anteroposterior location of the artificial disc than to the amount of anulus removed. Under 800 N axial compression, implanted models with an anteriorly placed artificial disc exhibited facet loads 2.5 times greater than loads observed with the intact model, whereas posteriorly implanted models predicted no facet loads in compression. Implanted models with a posteriorly placed disc exhibited greater flexibility than the intact and implanted models with anteriorly placed discs. Restoration of the anterior longitudinal ligament reduced pedicle stresses, facet loads, and extension rotation to nearly intact levels. Conclusions. The models suggest that, by altering placement of the artificial disc in the anteroposterior direction, a surgeon can modulate motion-segment flexural stiffness and posterior load-sharing, even though the specific disc replacement design has no inherent rotational stiffness.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据