3.8 Article

The use of a bilaminate artificial skin substitute (Integra™) in acute resurfacing of burns:: an early experience

期刊

BRITISH JOURNAL OF PLASTIC SURGERY
卷 54, 期 3, 页码 208-212

出版社

CHURCHILL LIVINGSTONE
DOI: 10.1054/bjps.2000.3525

关键词

artificial skin; Integra; complications; case report

类别

向作者/读者索取更多资源

Integra(TM) artificial skin provides immediate full-thickness reconstruction for cutaneous bums. The clinical outcome appears to be superior in terms of final function and cosmesis. Consequently the use of such a skin substitute is being heralded as the future treatment of choice, particularly for massive burns where autologous donor skin is limited. The three cases reported here describe the senior author's early experience with Integra and highlight some of the difficulties and successes encountered. A high rate of dermal graft loss and slow epidermal engraftment have tempered the original enthusiasm, but with growing experience the final outcome justifies the continued use of Integra in our unit. (C) 2001 The British Association of Plastic Surgeons.