4.7 Article

Treatment of no-reflow and impaired flow with the nitric oxide donor nitroprusside following percutaneous coronary interventions: Initial human clinical experience

期刊

JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY
卷 37, 期 5, 页码 1335-1343

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/S0735-1097(01)01138-X

关键词

-

向作者/读者索取更多资源

OBJECTIVES The objective of this study was to test the hypothesis that the intracoronary administration of a direct donor of nitric oxide is a safe and effective method to treat impaired blood flow (no-reflow phenomenon) that occurs during percutaneous transluminal coronary interventions (PTCI). BACKGROUND The absence of blood flow or decreased blood how in a coronary artery following PTCI despite the presence of a patent epicardial vessel or graft is designated no-reflow or impaired flow. This alteration in blood flow is a serious complication of percutaneous revascularization strategies that results in an increased incidence of morbidity, myocardial infarction and mortality. METHODS Nineteen consecutive patients undergoing standard percutaneous revascularization procedures complicated bq either no-reflow or impaired flow that received intracoronary nitroprusside treatment were studied. One patient had two procedures performed on two separate grafts on two successive days. Interventions were performed on either saphenous vein grafts or native vessels and utilized angioplasty, stent deployment or rotational atherectomy strategies. Following interventions that were associated with impaired flow, varying total doses (of nitroprusside 50 to 1,000 mug) were administered into the coronary artery or saphenous vein graft. The angiographic archives before and after intracoronary administration of nitroprusside were analyzed for TIMI grade flow and a frame count method was used to quantitate blood flow velocity. RESULTS Following a PTCI that resulted in either no-reflow or impaired flow, nitroprusside (median dose 200 mug) was found to lead to a highly significant and rapid improvement in both angiographic flow (p < 0.01 compared with pretreatment angiogram) and blood flow velocity (p < 0.01 compared with pretreatment angiogram). No significant hypotension or other adverse clinical events were associated with nitroprusside administration. CONCLUSIONS The direct nitric oxide donor nitroprusside is an effective, safe treatment of impaired blood flow and no-reflow associated. with PTCI. The use of nitroprusside to treat syndromes secondary to microvascular dysfunction may provide a novel therapeutic strategy for treating no-reflow or impaired blood flow following percutaneous interventions. (J Am Cell Cardiol 2001;37:1335-43) (C) 2001 by the American College of Cardiology.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据