4.5 Article

The efficacy of direct current stimulation for lumbar intertransverse process fusions in an animal model

期刊

SPINE
卷 26, 期 9, 页码 1002-1007

出版社

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/00007632-200105010-00003

关键词

animal model; bone graft; DC electrical stimulation; spinal fusion

向作者/读者索取更多资源

Study Design. Posterolateral lumbar intertransverse process fusion using a rabbit model with autologous bone graft and direct current stimulation was compared with fusion achieved by using autologous bone graft alone. Objectives. To determine the efficacy of direct current electrical stimulation for the posterolateral lumbar intertransverse process fusion technique by using a 20-muA current and the more recently developed 60-muA current delivered by an implantable direct current stimulator. Summary of Background Data. Previous studies have demonstrated a positive effect of direct current electrical stimulation on posterior spinal fusion techniques. However, until recently, the environment of an intertransverse fusion was not well simulated. The current research examined the posterolateral lumbar intertransverse process fusion technique with direct current electrical stimulation using a rabbit model. This appears to parallel human fusion techniques more closely and allows for lower cost and technical ease. Methods. In this study, 44 adult New Zealand white rabbits underwent an L5-L6 intertransverse process fusion. All the fusions used an autologous bone graft obtained from bilateral posterior iliac crests. A device was implanted in all the rabbits subcutaneously, and they were divided randomly into three groups: a sham or non-functioning group, a 20-muA low-current stimulator group, and a 60-muA higher-current stimulator group. Spinal fusion was evaluated radiographically, histologically, and manually as well as by biomechanical testing 5 weeks after surgery. Results. Radiographic grades, manual palpation, biomechanical strength, and stiffness showed an increasing trend from sham or inactive stimulator groups to low-current and then to high-current stimulator groups. Histologic analysis revealed that the higher-current stimulator showed that, statistically, the healing response of the host tissue to the autograft had increased significantly, as compared with the sham. Conclusions. Direct current electrical stimulation is efficacious in improving both the healing rate and strength in this posterolsteral lumbar fusion model. In addition, it appears that this effect is enhanced by increasing the stimulation current from 20 muA to 60 pA.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据