4.5 Article

Curing potential of dual-polymerizable resin cements in simulated clinical situations

期刊

JOURNAL OF PROSTHETIC DENTISTRY
卷 85, 期 5, 页码 479-484

出版社

MOSBY-ELSEVIER
DOI: 10.1067/mpr.2001.114842

关键词

-

向作者/读者索取更多资源

Statement of problem. Little is known about the ability of dual-polymerizable resin cements to polymerize when they are used in various clinical scenarios. Purpose. This study was conducted to determine whether any of 6 commercially available dual-polymerizable resin cements should be classified as an all-purpose resin cement. Material and methods. Chemical conversion values (C=C converted to C-C, or the extent of the curing reaction) of 6 commercially available dual-polymerizable resin cements were determined with infrared spectroscopy in 5 clinically relevant scenarios. Scenarios included: using each cement in a dual-polymerizable mode (mixing of 2 pastes); light polymerizing curing through Mylar sheets (dual-Mylar), which served as the control; light polymerizing through 3-mm porcelain (dual-3 mm); and no exposure to light (dual-no light). The single-component light-polymerizable product was also tested as follows: exposed directly through Mylar (light-Mylar) or exposed through 3 mm of porcelain (light-3 mm). Results. For each product, dual-Mylar treatment yielded the highest conversion value of all treatments (control for each product). For all products, dual-3 mm conversion was at least 97% of control and equivalent to control, with the exception of Lute-It!. Dual-no light conversion was less than control treatment but at least 86% of control for all products except for Variolink II (62% of control). For all products in dual-no light mode, except Choice and Variolink II, conversion was at least equal to the light-Mylar values. Only 1 product (Variolink II) did not demonstrate increased conversion values for dual-Mylar compared with light-Mylar treatments. For most other products (Calibra, Insure, and Lute-It!), conversion values for light-3 mm were significantly less than for light-Mylar. Conversion values for Nexus, Choice, and Variolink II were equivalent between light-Mylar and light-3 mm treatments. Conclusion. The choice of a dual-polymerizable cement should be based on its intended use because not all products polymerize adequately in every clinical situation. Although no cement met the stated criteria for an all-purpose cement, those tested did produce a range of product-specific results.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据