4.4 Article

High temporal resolution dynamic contrast MRI in a high risk group for placenta accreta

期刊

MAGNETIC RESONANCE IMAGING
卷 19, 期 5, 页码 635-642

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/S0730-725X(01)00388-5

关键词

dynamic contrast MRI; placenta abnormalities; placenta accreta; intrauterine exposure of contrast material

向作者/读者索取更多资源

Antenatal diagnosis of placenta accreta with MR is not easy even now because T-2-weighted images (T2WI) cannot differentiate chorionic villi from decidua basalis. We performed dynamic contrast MRI to study whether trophoblastic villi could be separately demonstrated from the decidua basalis, and whether the contrast resolution between the placenta and myometrium could improve compared to T2WI. Six pregnant women with prior cesarean section were examined at 34-38 gestational weeks. Sagittal T-2-weighted images with fast spin echo sequences and dynamic contrast studies with fast field echo sequence every 10-14 s after contrast injection were performed. We analyzed the enhancing pattern of the placenta and compared the contrast between placenta and myometrium. We reviewed medical records to identify complications during the placental delivery and the complications of their newborns. In the early phase after contrast enhancement, multiple foci of the strong lobular enhancement were observed in all cases. Other parts of placenta were slowly but strongly enhanced following them. We speculated that the former corresponded to intervillous space and the latter decidua basalis. The contrast between placenta and myometrium tended to be distinct near the inner cervical os on both T2WI and dynamic contrast study. On the other hand, it was indistinct in the upper part of the uterine body on T2WI despite it was clearly demonstrated on dynamic contrast study. The placentae were delivered without any complication in all cases. Although two neonates showed fetal distress, none of the infant remained any sequelae at the time of the discharge. The other four were well although one of them complicated with meconium staining. As dynamic contrast MRI can differentiate chorionic villi and decidua basalis, and can provide excellent contrast between placenta and myometrium at anywhere within the uterus, it may be a promising technique for antepartum diagnosis of the placenta accreta. (C) 2001 Elsevier Science Inc. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据