4.6 Article

Measurement of twitch transdiaphragmatic, esophageal, and endotracheal tube pressure with bilateral anterolateral magnetic phrenic nerve stimulation in patients in the intensive care unit

期刊

CRITICAL CARE MEDICINE
卷 29, 期 7, 页码 1325-1331

出版社

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/00003246-200107000-00005

关键词

intensive care; ventilatory muscles; muscle weakness; mechanical ventilation; mechanical ventilator weaning; respiration artificial; inspiratory positive pressure ventilation; magnetic stimulation; phrenic nerves; transdiaphragmatic pressure

向作者/读者索取更多资源

Objective: In the critically ill, respiratory muscle strength usually has been assessed by measuring maximum inspiratory pressure. The maneuver is volitional, and results can be unreliable. The nonvolitional technique of bilateral anterolateral magnetic stimulation of the phrenic nerves, producing twitch transdiaphragmatic pressure, has been successful in normal subjects and ambulatory patients. In this study we used the technique in the intensive care unit and explored the measurement of twitch endotracheal tube pressure as a less invasive technique to assess diaphragmatic contractility. Design: Clinical study to quantify diaphragm strength in the intensive care unit. Setting: patients from three London teaching hospital intensive care units and high-dependency units. Patients: Forty-one intensive care patients were recruited. Of these, 33 (20 men, 13 women) were studied. Interventions: Esophageal and gastric balloon catheters were passed through the anaesthetized nose, and an endotracheal tube occlusion device was placed in the Ventilation circuit, next to the endotracheal tube. Two 43-mm magnetic coils were placed anteriorly on the patient's neck, and the phrenic nerves were stimulated magnetically. Measurements and Main Results: On phrenic nerve stimulation, twitch gastric pressure, twitch esophageal pressure, twitch transdiaphragmatic pressure, and twitch endotracheal tube pressure were measured. Forty-one consecutive patients consented to take part in the study, and twitch pressure data were obtained in 33 of these. Mean transdiaphragmatic pressure was 10.7 cm H(2)O, mean twitch esophageal pressure was 6.7 cm H(2)O, and mean twitch endotracheal tube pressure was 6.7 cm H(2)O. The mean difference between twitch esophageal pressure and twitch endotracheal tube pressure was 0.02 cm H(2)O. Correlation of the means of twitch endotracheal tube pressure to twitch esophageal pressure was 0.93, and that for twitch endotracheal tube pressure to transdiaphragmatic pressure was 0.78. Conclusions: Transdiaphragmatic pressure can be measured in the critically ill to give a nonvolitional assessment of diaphragm contractility, but not all patients can be studied. At present, the relationship of twitch endotracheal tube pressure to transdiaphragmatic pressure is too variable to reliably represent a less invasive measure of diaphragm strength.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据