4.7 Article

Development of a luminol-based chemiluminescence flow-injection method for the determination of dichlorvos pesticide

期刊

TALANTA
卷 54, 期 6, 页码 1185-1193

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/S0039-9140(01)00388-5

关键词

chemiluminescence; flow inject analysis; dichlorvos pesticide; cyltrimethylammonium bromide

向作者/读者索取更多资源

A simple, fast chemiluminescence (CL) flow-injection method based on the reaction of luminol with H2O2 in the presence of a cationic surfactant (cyltrimethylammonium bromide, CTMAB) has been described for the direct determination of dichlorvos pesticide (DDVP). Under the optimal conditions, the CL intensity was linear to the DDVP concentration in the range of 0.02-3.1 mug ml(-1) (r = 0.9998, n = 10). The relative standard deviation was 3.4% at 0.35 mug ml(-1) (n = 10), with a detection limit (3 sigma) of 0.008 mug ml(-1) DDVP. The possible reaction mechanism was also discussed. This method has been successfully applied to the determination of trace DDVP residue in vegetable sample and results have been compared with that of the UV method. (C) 2001 Elsevier Science B.V. All rights reserved.