4.5 Article

Speech recognition in noise as a function of the number of spectral channels: Comparison of acoustic hearing and cochlear implants

期刊

JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA
卷 110, 期 2, 页码 1150-1163

出版社

AMER INST PHYSICS
DOI: 10.1121/1.1381538

关键词

-

资金

  1. NIDCD NIH HHS [R01-DC-01526, N01-DC-92100] Funding Source: Medline

向作者/读者索取更多资源

Speech recognition was measured as a function of spectral resolution (number of spectral channels) and speech-to-noise ratio in normal-hearing (NH) and cochlear-implant (CI) listeners. Vowel, consonant, word, and sentence recognition were measured in five normal -hearing listeners, ten listeners with the Nucleus-22 cochlear implant, and nine listeners with the Advanced Bionics Clarion cochlear implant. Recognition was measured as a function of the number of spectral channels (noise bands or electrodes) at signal-to-noise ratios of + 15, + 10, +5, 0 dB, and in quiet. Performance with three different speech processing strategies (SPEAK, CIS, and SAS) was similar across all conditions, and improved as the number of electrodes increased (up to seven or eight) for all conditions. For all noise levels, vowel and consonant recognition with the SPEAK speech processor did not improve with more than seven electrodes, while for normal-hearing listeners, performance continued to increase up to at least 20 channels. Speech recognition on more difficult speech materials (word and sentence recognition) showed a marginally significant increase in Nucleus-22 listeners from seven to ten electrodes. The average implant score on all processing strategies was poorer than scores of NH listeners with similar processing. However, the best Cl scores were similar to the normal-hearing scores for that condition (up to seven channels). CI listeners with the highest performance level increased in performance as the number of electrodes increased up to seven, while CI listeners with low levels of speech recognition did not increase in performance as the number of electrodes was increased beyond four. These results quantity the effect of number of spectral channels on speech recognition in noise and demonstrate that most Cl subjects are not able to fully utilize the spectral information provided by the number of electrodes used in their implant. (C) 2001 Acoustical Society, of America.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据