期刊
APPLIED SPECTROSCOPY
卷 55, 期 9, 页码 1138-1150出版社
SOC APPLIED SPECTROSCOPY
DOI: 10.1366/0003702011953388
关键词
on-line; Raman spectroscopy; process control; titanium dioxide
A system based on Raman spectroscopy has been developed for closed-loop control during the manufacture of titanium dioxide (TiO2). Spectra were obtained in the 50 to 700 cm(1) range using excitation at similar to 532 nm and a fixed transmission-grating spectrograph coupled to a CCD detector. Quantitation has been achieved by linear interpolation based on the integrated intensity of phonons at 142 and 610 cm(-1) due to anatase and rutile phases, respectively. The spectroscopic instrumentation has been integrated with a powder sampling system and installed on four full-scale manufacturing plants. Fiber coupling (up to 100 m) has been employed, and each spectrometer system is multiplexed to three sampling heads. Spectra are corrected for changes in sample temperature, and the systems are designed to be fully automatic and require no user intervention.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐