4.6 Article

Transforming growth factor β-coated platinum coils for endovascular treatment of aneurysms:: An animal study

期刊

NEUROSURGERY
卷 49, 期 3, 页码 690-694

出版社

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/00006123-200109000-00030

关键词

aneurysm; animal model; embolization; growth factors

向作者/读者索取更多资源

Objective: To test the hypothesis that coating platinum coils with transforming growth factor beta (TGF beta) would improve the cellular proliferation within experimental aneurysms relative to uncoated coils. Materials and methods: Elastase-induced saccular aneurysms were created in 12 New Zealand White rabbits. These aneurysms were embolized with platinum coils, either control (unmodified) coils or test (coated with TGF beta) coils. Subjects were killed either 2 weeks (n = 3, control; n = 3, test) or 6 weeks (n = 3, control; n = 3, test) after embolization. Aneurysm tissue was embedded in plastic, sectioned, and stained with hematoxylin and eosin. The thickness of tissue covering the coils at the coil-lumen interface was measured by use of a digital microscope, and was compared between groups by use of the Student's t test (P less than or equal to 0.05). Results: Two-week implantation samples demonstrated mean thickness of tissue overlying TGF beta -coated coils of 36 +/- 15 mum and mean thickness of overlying control coils of 3 +/-5 mum, indicating significantly thicker tissue growth covering test versus control coils (P = 0.02). Six-week implantation samples demonstrated mean thickness of tissue overlying TGF beta -coated coils of 86 +/- 74 mum versus mean thickness overlying control coils of 37 +/-6 mu; this difference did not reach statistical significance (P = 0.30). Thickness of tissue covering TGF beta -coated coils did not change significantly from 2 to 6 weeks (P = 0.31). Tissue thickness over control coils increased significantly between 2 and 6 weeks (P = 0.002). Conclusion: TGF beta -coated platinum coils undergo earlier cellular coverage than standard platinum coils, but differences in coverage between coated and control coils are no longer present at later time points. These data suggest that improvements in intra-aneurysmal cellular proliferation resulting from coil modifications, although significant in the early postembolization phase, may dissipate over time.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据