4.5 Article

The use of cross-correlation analysis between high-frequency ultrasound images to measure longitudinal median nerve movement

期刊

ULTRASOUND IN MEDICINE AND BIOLOGY
卷 27, 期 9, 页码 1211-1218

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/S0301-5629(01)00413-6

关键词

median nerve; speckle tracking; ultrasound; cross-correlation; carpal tunnel syndrome; biomechanics

向作者/读者索取更多资源

Impaired nerve movement can lead to nerve injury (e.g., carpal tunnel syndrome). A noninvasive method to measure nerve movement in longitudinal section would enable an extensive analysis of nerve entrapment syndromes. A method has been developed using cross-correlation between successive high-frequency ultrasound (US) images to measure longitudinal movement of nerve and muscle. Control phantom experiments demonstrated the accuracy and reliability of this method at velocities of 1-10 mm/s. Increasing the frame interval between the compared frames enabled the accurate calculation of slower velocities. The correlation algorithm successfully measured relative movement when the US transducer was moved 1-3 mm over the surface of the forearm. Median nerve movement was repeatedly measured in the forearm during 30 degrees passive wrist extension in three subjects (range 2.63-4.12 mm) and index finger extension in seven subjects (range 1.59-4.48 mm). Median nerve movement values were consistent with those from cadaver studies.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据