4.5 Article

Influence of debonding in ground heat exchangers used with geothermal heat pumps

期刊

GEOTHERMICS
卷 30, 期 5, 页码 527-545

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/S0375-6505(01)00011-6

关键词

geothermal heat pumps; grout; debonding; thermal resistance; heat transfer

向作者/读者索取更多资源

Debonding in ground heat exchangers used with geothermal heat pumps may occur for a variety of reasons, such as shrinkage of the backfill materials or surrounding formation, improper grouting and thermal mismatch. The effect of thermal contact resistance on the heat conduction due to debonding in ground heat exchangers was investigated using a set of one-dimensional simplified analytical models as well as two-dimensional finite element models. From the cases studied, debonding at the backfill/pipe interface was found to be of greater significance than debonding between grout and surrounding formation. (C) 2001 CNR. Published by Elsevier Science Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据