3.9 Article

Development and evaluation of high throughput functional assay methods for hERG potassium channel

期刊

JOURNAL OF BIOMOLECULAR SCREENING
卷 6, 期 5, 页码 325-331

出版社

SAGE PUBLICATIONS INC
DOI: 10.1177/108705710100600506

关键词

-

向作者/读者索取更多资源

Three functional hERG channel assay methods have been developed and evaluated. The methods were tested against five known hERG channel inhibitors: dofetilide, terfenadine (Seldane), sertindole (Serdolect), astemizole (Hismanal), and cisapride (Propulsid). The DiBAC(4)(3)-based assays were found to be the most economical but had high false-hit rates as a result of the interaction of dye with the test compounds. The membrane potential dye assay had fewer color-quenching problems but was expensive and still gave false hits. The nonradioactive Rb+ efflux assay was the most sensitive of all the assays evaluated and had the lowest false-hit rate.