Peritoneography in the assessment of peritoneal cerebrospinal fluid absorption potential for distal ventriculoperitoneal shunt catheter placement: Technical case report

期刊

NEUROSURGERY
卷 49, 期 5, 页码 1267-1269

出版社

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/00006123-200111000-00050

关键词

cerebrospinal fluid; peritoneography; ventriculoperitoneal shunt

向作者/读者索取更多资源

OBJECTIVE AND IMPORTANCE: Distal ventriculoperitoneal shunt failure has been associated with absorption failure secondary to previous peritonitis. This assumption has caused surgeons to seek alternate sites for distal catheter placement. We propose that the absorptive potential of the peritoneal cavity should be assessed before that site is discounted for catheter placement. CLINICAL PRESENTATION: The case of a 14-month-old male patient is presented, demonstrating multiple ventriculoperitoneal shunt placement procedures and a diagnostic dilemma with respect to distal shunt placement. Peritoneography was performed to demonstrate peritoneal fluid absorption, allowing subsequent placement of a new distal shunt catheter with good clinical results. TECHNIQUE: Using aseptic technique, a 24-gauge spinal needle was inserted in the midline of the abdomen and water-soluble contrast material was instilled. Delayed radiographs delineated peritoneal adhesions and demonstrated renal excretion of the contrast material, confirming peritoneal absorption. CONCLUSION: The peritoneal cavity remains the site of choice for distal shunt catheter placement. If failure of peritoneal cerebrospinal fluid absorption is suspected as a cause of shunt failure, then peritoneography with water-soluble contrast material may be safely used to demonstrate the adequacy of fluid absorption before a secondary site is chosen.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据