4.7 Article

Ventricular assist device in severe heart failure - Effects on cytokines, complement and body weight

期刊

EUROPEAN HEART JOURNAL
卷 22, 期 24, 页码 2275-2283

出版社

W B SAUNDERS CO LTD
DOI: 10.1053/euhj.2001.2693

关键词

chronic heart failure; ventricular assist device; cytokines; tumour necrosis factor alpha

向作者/读者索取更多资源

Aims Inflammatory and immune activation and body wasting are important features of end-stage chronic heart failure. It is not known whether restoration of cardiac output by assist device implantation can improve these abnormalities. Methods We studied 48 patients (39 males; age 45 +/-2 years) with NYHA class IV heart failure. All patients underwent ventricular assist device implantation for endstage heart failure as a bridge to cardiac transplantation. Plasma levels Of tumour necrosis factor alpha, and its receptors, interleukin-6, elastase, activated complement, and soluble CD14 receptors were measured at the time of operation and in survivors at I week (n=46), 40 days (n=35) and 90 days (n=26). Follow-Lip was for a minimum of I year. Results One-year survival was 35% (95% Cl: 22-49%). Body mass index was the only predictor of survival (body mass index > 25 (n=16); survival 63 (39-86)%; body mass index < 25 (n=32), survival 22 (7.5-36)%: P=0.003). Tumour necrosis factor alpha fell from 9.66 +/-1.33 pg.ml(-1) to 4.2 +/-1.0 at I week (P=0.008), but returned to preoperative levels at 90 days. Interleukin-6, activated complement and elastase fell progressively to 40 days, but were rising at 90 days. There was no change in tumour necrosis factor receptor. There was a gradual rise in CD14 (3.99 +/-0.15 mug.ml(-1) at baseline, 5.02 +/-0.39 at 90 days, P=0.006). After surgery, body weight fell from 80 +/-2 to 73 +/-2 kg by I month (P <0.001) and to 72 +/-2 kg at 90 days. Conclusions Ventricular assist device implantation results in a short-term fall in tumour necrosis factor alpha and interleukin-6, but no change in CD14 or tumour necrosis factor receptor, suggesting that the pathophysiological process resulting in inflammation was not altered by left ventricular assist device implantation. Low body mass index is related to poor outcome after assist device implantation, and no weight gain. (C) 2001 The European Society of Cardiology.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据